General Specifications
Up to 2000 square feet can be installed using thermostatic units.
- Listings: ETL/UL certified for the United States under UL 1693 ETL 4007353, CE 120509, TUV K5140/E112.
- Controls: The film heater must be controlled by a CarbonicHeat approved line voltage thermostat to sense floor heat.
- Voltage: 120 VAC Max. 100 sq. ft. (9.29 sq. meters) 50/60 Hz, 240 VAC Max. 200 sq. ft. (18.58 sq. meters) 50/60 Hz.
- Watts: 15 W/sq. ft. (51 Btu/sq. ft.), 166.1 W/m².
- Maximum circuit load: 15 amperes.
- Maximum circuit overload protection: 20 amp circuit breaker GFCI (Ground Fault Circuit Interrupter) required for each circuit (included in thermostat control)
- Maximum bend radius: Not to exceed 90 degrees. Do not bend the heating film.
- Maximum exposure temperature:(Continuous and storage) 150ºF (65.5ºC).
- Minimum installation temperature: 50ºF (10ºC)
PTC (Positive Temperature Control). Nanocarbon technology limits the maximum temperature for safety. Reduces current consumption.
- 15 watts per square foot of power consumption.
- 51 BTU per square foot of heat output.
- 100% conversion of electrical energy into heat. Efficient.
- 120 volt or 240 volt operation.
- 15 amp circuit.
- 1/16 inch thick, completely smooth surface.
- Width: either 20 inches or 40 inches.
- Length: Up to 150 feet.
- PET polyethylene layers.
- PP polypropylene layers.
- The nonwoven polyester outer layer adheres aggressively to thin mortar or other adhesives.
- Shipping container: 42″ x 9″ x 9.